logo
Found 731 results for "

data center uninterruptible power supply

"
Qualità 240KVA 3 fase Visench Fortress 3p3p 240KW OEM Power Supply Ups online per data center fabbrica

240KVA 3 fase Visench Fortress 3p3p 240KW OEM Power Supply Ups online per data center

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Qualità R410 refrigerante 5000 m3/h flusso d'aria condizionatore d'aria di precisione a livello di stanza per data center fabbrica

R410 refrigerante 5000 m3/h flusso d'aria condizionatore d'aria di precisione a livello di stanza per data center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Qualità 380VAC/50HZ Visench CRA Serie Climatizzatore di precisione a livello di stanza per Data Center fabbrica

380VAC/50HZ Visench CRA Serie Climatizzatore di precisione a livello di stanza per Data Center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Qualità 8KW 13KW condizionatore d'aria industriale laboratorio Data Center Sala server raffreddamento solo categoria fabbrica

8KW 13KW condizionatore d'aria industriale laboratorio Data Center Sala server raffreddamento solo categoria

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Qualità Ventilatore EC Visench CRA Serie 12,5KW Climatizzatore di precisione a livello di stanza per data center fabbrica

Ventilatore EC Visench CRA Serie 12,5KW Climatizzatore di precisione a livello di stanza per data center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Qualità Climatizzatore industriale a pianta per laboratorio e data center fabbrica

Climatizzatore industriale a pianta per laboratorio e data center

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Qualità Climatizzatore ad alta precisione industriale 8KW 13KW per laboratorio Data Center Server Room fabbrica

Climatizzatore ad alta precisione industriale 8KW 13KW per laboratorio Data Center Server Room

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Qualità Alto livello di sicurezza Visench CRA 12,5KW 25KW 40KW 50KW 60KW Climatizzatore industriale di precisione per data center fabbrica

Alto livello di sicurezza Visench CRA 12,5KW 25KW 40KW 50KW 60KW Climatizzatore industriale di precisione per data center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Qualità 5000m3/h Visench CRA 12.5KW Servizi di precisione aria condizionata per laboratorio Data Center fabbrica

5000m3/h Visench CRA 12.5KW Servizi di precisione aria condizionata per laboratorio Data Center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible